|
|
|
|
Changelog for sane-saned-1.3.1.git20240914-3.2.x86_64.rpm :
* Mon Jul 01 2024 Stephan Hemeier - add Requires: libnsl1 for Leap 15.6 to get it working with brscan3 from Brother * Fri Mar 01 2024 Stephan Hemeier - Use %%patch -P N instead of deprecated %%patchN.- clean up spec File and Patches * Sat Jan 27 2024 Stephan Hemeier - Update to Version 1.2.1.git20240127 * Thu Jan 18 2024 Stephan Hemeier - Update to Version 1.2.1.git20240118 * Sun Oct 02 2022 Stephan Hemeier - Update to Version 1.1.1.git20221002 * Fri Jan 28 2022 Stephan Hemeier - Update to Version 1.1.1.git20220128 * Fri Jan 28 2022 Stefan Brüns - Upgraded to sane-backends version 1.1.1 * Backends + epson2: Fixed support for many scanners that don\'t support focus command. + epson2: Improve reliability of long scans. + epsonds: Implemented support for the following Epson scanners: - DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410, DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W, DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W - ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W, ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB, ES-60WW, ES-65WR, - ET-2700 Series, ET-2710 Series, ET-2810 Series, ET-M2140 Series, ET-M3140 Series, - EW-052A Series, - FF-680W, - L3150 Series, L3200 Series, L3210 Series, L3250 Series, L4150 Series, - M2140 Series, M3140 Series, - RR-60, RR-600W, RR-70W, - XP-2100 Series, XP-2150 Series + epson2: Marked XP-452 455 series as supported in documentation + escl: Fixed scanning problems on certain scanners due to incorrect URL being used (#479) + escl: Fixed support for different resolutions when using JPEG format + escl: Fixed handling of ipp-usb redirects to localhost which previously caused certain scanners to be always reported as busy + escl: Added support for Brother DCP-J772DW and Epson ET-2750 scanners + escl: Marked the following scanners as supported in documentation: - Canon PIXMA G4511 - Canon PIXMA TR4550 Series - Canon PIXMA TR4551 Series - Epson ET-6100 + escl: Implemented support for disabling PDF output on scanners where it\'s broken (#510) + escl: Implemented support for Canon PIXME TR4520 and TR7500 scanners + genesys: Improved scan quality on Canon LiDE 35/40/50/60 by using brighter LED illumination + genesys: Fixed control of contrast and brigthness on certain scanners (#271) + genesys: Fixed crashes when handling slightly unexpected conditions (#464) + genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner + genesys: Fixed button support on HP ScanJet G4010 + genesys: Fixed compilation on gcc-4.8 + genesys: Fixed incorrect LED exposure calculation leading to wrong color balance on certain resolutions on gl841 scanners + genesys: Improved gray scan quality on Canon LiDE 110, 120, 210, 220 (#106, #52) + genesys: Fixed issue of motor becoming stuck at certain resolutions on Canon LiDE 50 and possibly other gl841 scanners (#357) + genesys: Fixed periodic black lines in gray scans on Canon LiDE 80 + genesys: Removed support for broken 75 and 100 dpi hardware resolutions to fix preview scans (#383). These resolutions did not have any benefit compared to next smallest 150 dpi resolution + genesys: Add support for running in embedded environments that don\'t support threads + genesys: Fixed gray scans to use white color for illumination instead of red on Canon LiDE 35/40/50/60 and potentially other gl841 scanners. Old behavior can be restored via the color filter setting to select specific color component for the gray scan + genesys: The genesys backend is now distributed under GPL v2 or later license. Previously there existed an exception that allowed additional uses of the backend + gt68xx: Fixed several memory issues that can potentially lead to crashes or increased memory use + hp4200: Fixed crash when using HP ScanJet 4200C (#454) + microtek: Fixed support for embedded platforms using uclibc + pieusb: Implemented support for Reflecta RPS 10M scanner + pieusb: Fixed support for automatically advancing slides on DigitDia 4000 + pixma: Fixed compliation with NDEBUG macro defined + pixma: Marked Canon PIXMA G4511 as supported in documentation + scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series as supported * Frontends + Improved documentation of scanimage concerning options provided by backends + scanimage: Improved help to specify which options are advanced + scanimage: Implemented support for PDF output format- Cleanup create_hpaio.desc_from_models.dat: * Remove scanners unsupported by hplip (scan-type < 0) * Simplify and significantly speed it up * Sun Dec 12 2021 Stephan Hemeier - Update to Version 1.0.33.git20211212 * Sat Oct 09 2021 Stephan Hemeier - Update to Version 1.0.33.git20211009 * Thu Mar 04 2021 Stephan Hemeier - Upgrade to Version 1.0.32.git20210304- Add sane-epson2_ops.patch * Mon Feb 15 2021 Stephan Hemeier - Upgrade to Version 1.0.32.git20210215 * Mon Feb 15 2021 Stefan Brüns - Remove udev rules mangling for USB devices (ATTR vs ATTRS) (!510)- Do no add SCSI id twice for EPSON Perfection 1640SU (!509) * Mon Feb 15 2021 jsmeixAATTsuse.de- Upgraded to sane-backends version 1.0.32 Changes since 1.0.31 see https://gitlab.com/sane-project/backends/-/blob/master/NEWS Numbers of the form \'(#NNN)\' usually mean upstream issues like https://gitlab.com/sane-project/backends/-/issues/NNN and numbers of the form \'(!MMM)\' usually mean upstream merge requests like https://gitlab.com/sane-project/backends/-/merge_requests/MMM Backends * all backends now respect the \'local_only\' parameter when \'true\' is passed to \'sane_get_devices()\' in that they do not actively go out looking for networked devices (!502) * \'artec_eplus48u\': fixes configuration for AstraSlim SE (!545) * \'avision\': adds the AV186+ and AV188 as supported (!532) * \'avision\': fixes doubled height issue (#402) * \'avision\': fixes a debug message and compiler warning (!515) * \'canon_dr\': adds support for the DR-C120 and DR-C130 (#175) * \'canon_dr\': adds support for uploading of fine calibration uploads * \'canon_dr\': enables fine calibration for the P-208 * \'canon_dr\': improves DR-C225 support (#431) * \'canon_lide70\': adds support for document scanning on the Canon LiDE 600(F), thanks to a hardware donation by Georg Sauthoff * \'dll\': fixes a memory leak (!537) * \'epson2\': adds support for the ET-2600 (#395) * \'epson2\': adds autofocus support for devices that support it (!531) * \'epson2\': fixes brightness support for DS-G20000/12000XL (!529) * \'epson2\': fixes an unchecked return value issue (!526) * \'escl\': adds support for brightness, threshold, sharpen and contrast options (!527, !528) * \'escl\': adds support for LaserJet FLowMFP M578 and MFP M630 (#424) * \'escl\': adds support for DeskJet 2710, 2723 (!519) and 3760 (!554) * \'escl\': adds support for the PIXMA TS-5351 (!544) and MG5765 (!517) * \'escl\': adds support for the Brother HL-L258DW (!517) * \'escl\': fixes Avahi device discovery (!536) * \'escl\': fixes crashes for devices without a flatbed (!554) * \'escl\': fixes segfaults in option handling (!557) * \'escl\': fixes sleep mode (!577) * \'escl\': fixes builds without libpoppler-glib-dev (#422) * \'escl\': fixes a memory issue in its capability handling (#425) * \'fujitsu\': fixes brightness/contrast for the iX500 * \'fujitsu\': fixes memory corruption for duplex scans * \'genesys\': disables support for CanoScan 4400F to prevent possible physical damage (#436) * \'gt68xx\': fixes scan cancellation logic (#356) * \'pixma\': adds untested support for models released in 2020 (!553) * \'pixma\': adds support for ADF scans on the i-SENSYS MF260 * \'pixma\': adds support for PIXMA M340 buttons and ADF status (!513) * \'pixma\': adds an option to control when to calibrate (#321) * \'pixma\': fixes support for the MX492 (!548) * \'pixma\': fixes ADF support for the MX490 Series * \'pixma\': fixes max resolution for ADF scans on the PIXMA M320 (#364) * \'pixma\': fixes compile errors when libxml2 is not available (#345) * \'plustek\': fixes CanoScanN650u discovery (#137) * \'test\': fixes several memory leaks (!537) Frontends * \'saned\': add support for listening on a custom or ephemeral port via a new \'-p\'/\'--port\' option (!549) * \'scanimage\': fixes crashes for multi-pass and handheld scans (#408) * \'scanimage\': fixes a memory leak (!551) * \'scanimage\': fixes option handling for non-compliant backends (#362) Documentation * updates our copy of the GPL with the FSF\'s current postal address. This changes references to the Library GPL (LGPL-2.0) into refs to the Lesser GPL (LGPL-2.1) but does *not * affect the licensing of our backends (#320). * source code now points to the Free Software Foundation\'s website for copies of the GPL and LGPL (#320) * updates translations for British English and Ukrainian * adds a pointer to our Ubuntu PPA for pre-built binaries * adds SCSI IDs for the EPSON Perfection 1640SU (!509) * fixes a boat-load of spelling mistakes (!516, thanks AATTmarschap) * updates description files for \'scangearmp2\' and \'utsushi\' external backends Build * removes support for \'automake\' maintainer mode (!522) * removes \'sane\' subdirectory from the lock directory to fix issues when the lock directory is on \'tmpfs\' (#363) * adds support for builds using GitLab \"source\" tarballs (#248) * fixes static link scenarios (#124) * fixes \'python\' invocations to use the detected program (!525) * disables \'genesys\' testsuite when that backend is not built (#354) * suppresses warnings about obsolete autoconf macros (#122) * fixes availability of sane-backends.pot file inputs (#344) * fixes \'configure.ac\' for use with \'autoconf-2.70\' (#409) * removes CVS keywords from the source to ease use by downstreams that still use CVS (!547) Miscellaneous * udev rules now trigger on all events other than \'remove\' (!541). This aims to address a kernel API change introduced in 4.14. The new behaviour may slow down udev\'s processing of kernel events when still using our plain \'udev\' or \'udev+acl\' rules, even though these have been optimized slightly (#341). If that bothers you, now is a good time to switch to our \'udev+hwdb\' rules in combination with the \'hwdb\' database if you have not done so already.
|
|
|